It’s Time to Retire ROSE Testing


Reading time ( words)

For decades now, the electronics industry has had a growing need to understand the impacts of chemical residues on PCB and PCBA reliability. Residues left from flux and other process chemistries can potentially lead to premature failure of assemblies once in the field. Understanding where such residues originate and their impact on product function is paramount to mitigating product failures due to cleanliness issues. One tool that has been used for decades to evaluate printed board and assembly cleanliness has been the resistivity of solvent extract (ROSE) test.

The ROSE test was developed in the early 1970s by the Naval Avionics Warfare Center in Indianapolis, Indiana. The early test used a squeeze bottle containing a solvent comprised of 75% 2-propanol and 25% deionized water (75/25). The surface of an assembly was rinsed with the 75/25 mixture and any material (e.g., flux) easily soluble in the mixture was dissolved and captured in a beaker. The resistivity of the captured solution was measured, and the result was expressed in terms of sodium chloride equivalents (NaCl eq.). Later versions of the test were automated and a 10.06 microgram (μg) of NaCl eq./in2 (1.56 μg of NaCl eq./cm2) limit was eventually ascribed to the test. That limit became enshrined in various military specifications, such as MIL-P-28809 and WS-6536 and eventually became the industry pass/fail standard. The limit persists today and is used across a wide base of material sets, from bare boards to assemblies to components.

Over the last two to three years, there has been considerable discussion within various IPC committees about the role of the ROSE test in today’s assembly environment. The transition from predominantly water wash processes to “no clean” has meant the advent of very different flux compositions. The question has been posed—on numerous occasions, we might add—as to whether the ROSE test is still a viable option for evaluating PCB and PCBA cleanliness. There have essentially been two camps of thought on the subject: those who want to continue using the test and re-invent it as a process control tool and those that think the test has run its useful course.

To update the test, IPC’s J-STD-001 committee commissioned a subgroup of users and subject matter experts to determine if there was a best-practices use that would bolster its continued application. Two conclusions were reached by that subgroup. First, the ROSE test should no longer be referred to as a cleanliness test, but as a process control tool. This was a reasonable conclusion since ROSE was never meant for cleanliness as industry had defined it. Second, users of the test must provide objective evidence, aside from just ROSE alone, to show that their manufacturing process is in control. More information about what the subgroup defined as “objective” evidence can be found in IPC-WP-019.

The statement made in the title to this article is where we want to focus most of our discussion. We are in the camp that believes the ROSE test provides little value for evaluating today’s assembly products and here’s why. The first significant concern with the validity of the ROSE test is the solvent. Back when the test was developed the predominant flux being used was heavily comprised of rosin (>30%). The 75/25 mixture was a very effective solvent for breaking down that flux and bringing it into solution. This is an important factor to consider because to accurately measure the amount of residual flux on a PCBA, you must first have a solvent that can dissolve it into solution. This is one of the major problems with the ROSE test today.

Why is the solvent an important consideration? Typically, four questions that are asked when performing cleanliness testing of assemblies. The questions are as follows:

1. What types of residues are on the surface of the assembly?

2. What are the concentrations of those residues?

3. Do those residues/concentrations pose any risk to product performance/function?

4. Where are the residues originating?

To have any hope of answering these questions, we need to consider a testing platform with two very specific attributes: selectivity and sensitivity. With the advances in board design, product miniaturization, process improvement and the myriad of chemicals used in assembly production today, a bulk-solvent measurement is not adequate for determining if there are any hidden residue traps.

To read the full version of this article, which appeared in the in the May 2018 issue of SMT007 Magazine, click here.

Share




Suggested Items

Mark Laing Talks ‘Sustainability in Manufacturing’

05/24/2023 | I-Connect007
Now available on Spotify, Episode 3 of I-Connect007’s new podcast, On the Line with… features an interview with Mark Laing, business development manager for digital industries software at Siemens. Laing discusses the role of electronics in achieving sustainability. Not only does the electronics industry have a primary role to play here, but it also contributes by creating products which enable other industries to monitor and optimize their sustainability practices.

Watch ‘Smarter Manufacturing Through Inspection,’ Final Episode of Smarter Manufacturing Micro Webinar Series

05/24/2023 | I-Connect007
Episode 12, “Smarter Manufacturing through Inspection,” from Koh Young’s new micro webinar series ‘Smarter Manufacturing Enabled with Inspection Data’ is available now.

Blackfox Shares Tips for Successful Skills Training

05/17/2023 | I-Connect007 Editorial Team
Successful skills training is a crucial part of the onboarding process and can take experienced staff members away from their primary jobs on the manufacturing floor. Effective training to onboard new employees can not only speed up the ramp-up times, but can also be customized to a company’s specific needs. We posed these four questions about new hire training to Sharon Montana-Beard, vice president of sales and operations at Blackfox.



Copyright © 2023 I-Connect007 | IPC Publishing Group Inc. All rights reserved.